Please use this identifier to cite or link to this item:
http://ri2.bib.udo.edu.ve:8080/jspui/handle/123456789/3849
Title: | COMPARACIÓN DE LOS PARÁMETROS HEMATOLÓGICOS, HEMOGASODINÁMICOS, ELECTROLÍTICOS Y PROTEÍNAS TOTALES EN Rynchops niger, Columbina squammata y Coturnix coturnix japonicus [Aves] |
Authors: | Alzola, Renny Muñoz, Jorge (jomunozg@yahoo.es) Marín, Gedio Lemus, Mairín |
Keywords: | R. niger C. squammata C. c. japonicus hematología gases electrolíticos proteínas blood gases electrolytes proteins |
Issue Date: | Dec-2006 |
Publisher: | Universidad de Oriente |
Abstract: | RESUMEN: Se compararon los parámetros hematológicos, electrolíticos, hemogasodinámicos y proteínas totales en Rynchops niger (Rynchopidae), Columbina squammata (Columbidae), Coturnix coturnix japonicus (Phasianidae). La extracción de la sangre se hizo por punción cardiaca directa; para determinar electrolitos intramusculares se tomó una porción de músculo pectoral. La hemoglobina fue cuantificada por el método de la cianometahemoglobina. El hematocrito se realizó en tubos capilares heparinizados, centrifugando a 7000 r.p.m durante 5 min. El contaje globular se determinó en una cámara de Neubauer. Los índices hematimétricos (VCM, HbCM, CHbCM) fueron calculados según Fisher (1958) y Castejón (1970). Los iones Na+ y K+ se determinaron por fotometría de llama de lectura directa, y el Cl¯, por titulación mercurimétrica; mientras los de Ca+ y Mg+ fueron cuantificados en un fotómetro de absorción atómica. La determinación de los iones intramusculares y plasmáticos fue similar, sólo que, previo a las diluciones, se realizó una digestión del tejido con ácido nítrico 70% en tubos de Kjendall. La determinación gasométrica se realizó con un microanalizador de pH y gases sanguíneos. Las proteínas totales del plasma fueron cuantificadas por el método de Lowry. Se obtuvieron diferencias significativas en los valores hematológicos, presentando R. niger los mayores valores promedios, y no se encontraron diferencias significativas para Na+, K+ y Cl¯, ni en los gases sanguíneos. las proteinas totales mostraron diferencias muy significativas. Estos resultados sugieren que las tres especies parecen tener mecanismos de regulación similares y que la variación en los parámetros hematológicos pudiera obedecer, en parte, a los hábitos alimentarios y ritmos circadianos diferentes en las tres especies. ABSTRACT: This paper reports on the physiological variability ranges of the hematological and electrolytic parameters as well as blood gas, and total protein counts in specimens of Rynchops niger (Rynchopidae), Columbina squammata (Columbidae), and Coturnix coturnix japonicus (Phasianidae). Blood extraction was practiced by direct heart puncture. Individuals were sacrificed and a portion of pectoral muscle was extracted to determine intramuscular electrolytes. Hemoglobin was quantified by means of the cyanometahemoglobin method Hematocrit was measured in heparinized capillary tubes, centrifuged at 7000 r.p.m for 5 minutes. Globular count was determined in a Neubauer camera. Hematimetric indices (VCM, HbCM, CHbCM) were calculated according to Fisher (1958) and Castejón (1970). Na+ and K+ ions were determined by direct reading of photometer flame. Cl- ions were determined by mercurymetric titration. Ca+ and Mg+ ions were quantified by atomic absorption spectrophotometry. Intramuscular ions were determined in a similar fashion, but only after the muscle tissue had been digested with 70% nitric acid in Kjendall tubes. Blood gases were measured in a pH and blood gas microanalyzer. Total proteins in plasma were quantified by the Lowry method. Significant differences were found in the hematological values, R. niger presenting the highest mean values. No significant statistical differences were found in Na+, K+, Cl-, or blood gases. Total proteins showed very significant differences. These results suggest that the three species seem to have similar regulation mechanisms, and that the variation in the hematological parameters is partially due to the different feeding habits and to the dissimilar circadian activity of the three species. |
URI: | http://ri2.bib.udo.edu.ve:8080/jspui/handle/123456789/3849 |
ISSN: | 1315-0162 |
Appears in Collections: | Revista SABER - Vol. 18 - Nros. 1 y 2 del año 2006 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
parametros hematologicos.pdf | 760,76 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Admin Tools